Configuring Monitor/OSD Interaction¶
After you have completed your initial Ceph configuration, you may deploy and run
Ceph. When you execute a command such as ceph health
or ceph -s
, the
Ceph Monitor reports on the current state of the Ceph Storage
Cluster. The Ceph Monitor knows about the Ceph Storage Cluster by requiring
reports from each Ceph OSD Daemon, and by receiving reports from Ceph
OSD Daemons about the status of their neighboring Ceph OSD Daemons. If the Ceph
Monitor doesn’t receive reports, or if it receives reports of changes in the
Ceph Storage Cluster, the Ceph Monitor updates the status of the Ceph
Cluster Map.
Ceph provides reasonable default settings for Ceph Monitor/Ceph OSD Daemon interaction. However, you may override the defaults. The following sections describe how Ceph Monitors and Ceph OSD Daemons interact for the purposes of monitoring the Ceph Storage Cluster.
OSDs Check Heartbeats¶
Each Ceph OSD Daemon checks the heartbeat of other Ceph OSD Daemons every 6
seconds. You can change the heartbeat interval by adding an osd heartbeat
interval
setting under the [osd]
section of your Ceph configuration file,
or by setting the value at runtime. If a neighboring Ceph OSD Daemon doesn’t
show a heartbeat within a 20 second grace period, the Ceph OSD Daemon may
consider the neighboring Ceph OSD Daemon down
and report it back to a Ceph
Monitor, which will update the Ceph Cluster Map. You may change this grace
period by adding an osd heartbeat grace
setting under the [osd]
section
of your Ceph configuration file, or by setting the value at runtime.
OSDs Report Down OSDs¶
By default, a Ceph OSD Daemon must report to the Ceph Monitors that another Ceph
OSD Daemon is down
three times before the Ceph Monitors acknowledge that the
reported Ceph OSD Daemon is down
. You can change the minimum number of
osd down
reports by adding an mon osd min down reports
setting (osd
min down reports
prior to v0.62) under the [mon]
section of your Ceph
configuration file, or by setting the value at runtime. By default, only one
Ceph OSD Daemon is required to report another Ceph OSD Daemon down
. You can
change the number of Ceph OSD Daemones required to report a Ceph OSD Daemon
down
to a Ceph Monitor by adding an mon osd min down reporters
setting
(osd min down reporters
prior to v0.62) under the [mon]
section of your
Ceph configuration file, or by setting the value at runtime.
OSDs Report Peering Failure¶
If a Ceph OSD Daemon cannot peer with any of the Ceph OSD Daemons defined in its
Ceph configuration file (or the cluster map), it will ping a Ceph Monitor for
the most recent copy of the cluster map every 30 seconds. You can change the
Ceph Monitor heartbeat interval by adding an osd mon heartbeat interval
setting under the [osd]
section of your Ceph configuration file, or by
setting the value at runtime.
OSDs Report Their Status¶
If an Ceph OSD Daemon doesn’t report to a Ceph Monitor, the Ceph Monitor will
consider the Ceph OSD Daemon down
after the mon osd report timeout
elapses. A Ceph OSD Daemon sends a report to a Ceph Monitor when a reportable
event such as a failure, a change in placement group stats, a change in
up_thru
or when it boots within 5 seconds. You can change the Ceph OSD
Daemon minimum report interval by adding an osd mon report interval min
setting under the [osd]
section of your Ceph configuration file, or by
setting the value at runtime. A Ceph OSD Daemon sends a report to a Ceph
Monitor every 120 seconds irrespective of whether any notable changes occur.
You can change the Ceph Monitor report interval by adding an osd mon report
interval max
setting under the [osd]
section of your Ceph configuration
file, or by setting the value at runtime.
Configuration Settings¶
When modifying heartbeat settings, you should include them in the [global]
section of your configuration file.
Monitor Settings¶
mon osd min up ratio
- Description
The minimum ratio of
up
Ceph OSD Daemons before Ceph will mark Ceph OSD Daemonsdown
.- Type
Double
- Default
.3
mon osd min in ratio
- Description
The minimum ratio of
in
Ceph OSD Daemons before Ceph will mark Ceph OSD Daemonsout
.- Type
Double
- Default
.75
mon osd laggy halflife
- Description
The number of seconds laggy estimates will decay.
- Type
Integer
- Default
60*60
mon osd laggy weight
- Description
The weight for new samples in laggy estimation decay.
- Type
Double
- Default
0.3
mon osd adjust heartbeat grace
- Description
If set to
true
, Ceph will scale based on laggy estimations.- Type
Boolean
- Default
true
mon osd adjust down out interval
- Description
If set to
true
, Ceph will scaled based on laggy estimations.- Type
Boolean
- Default
true
mon osd auto mark in
- Description
Ceph will mark any booting Ceph OSD Daemons as
in
the Ceph Storage Cluster.- Type
Boolean
- Default
false
mon osd auto mark auto out in
- Description
Ceph will mark booting Ceph OSD Daemons auto marked
out
of the Ceph Storage Cluster asin
the cluster.- Type
Boolean
- Default
true
mon osd auto mark new in
- Description
Ceph will mark booting new Ceph OSD Daemons as
in
the Ceph Storage Cluster.- Type
Boolean
- Default
true
mon osd down out interval
- Description
The number of seconds Ceph waits before marking a Ceph OSD Daemon
down
andout
if it doesn’t respond.- Type
32-bit Integer
- Default
300
mon osd down out subtree limit
- Description
The smallest CRUSH unit type that Ceph will not automatically mark out. For instance, if set to
host
and if all OSDs of a host are down, Ceph will not automatically mark out these OSDs.- Type
String
- Default
rack
mon osd report timeout
- Description
The grace period in seconds before declaring unresponsive Ceph OSD Daemons
down
.- Type
32-bit Integer
- Default
900
mon osd min down reporters
- Description
The minimum number of Ceph OSD Daemons required to report a
down
Ceph OSD Daemon.- Type
32-bit Integer
- Default
1
mon osd min down reports
- Description
The minimum number of times a Ceph OSD Daemon must report that another Ceph OSD Daemon is
down
.- Type
32-bit Integer
- Default
3
OSD Settings¶
osd heartbeat address
- Description
An Ceph OSD Daemon’s network address for heartbeats.
- Type
Address
- Default
The host address.
osd heartbeat interval
- Description
How often an Ceph OSD Daemon pings its peers (in seconds).
- Type
32-bit Integer
- Default
6
osd heartbeat grace
- Description
The elapsed time when a Ceph OSD Daemon hasn’t shown a heartbeat that the Ceph Storage Cluster considers it
down
.- Type
32-bit Integer
- Default
20
osd mon heartbeat interval
- Description
How often the Ceph OSD Daemon pings a Ceph Monitor if it has no Ceph OSD Daemon peers.
- Type
32-bit Integer
- Default
30
osd mon report interval max
- Description
The maximum time in seconds that a Ceph OSD Daemon can wait before it must report to a Ceph Monitor.
- Type
32-bit Integer
- Default
120
osd mon report interval min
- Description
The minimum number of seconds a Ceph OSD Daemon may wait from startup or another reportable event before reporting to a Ceph Monitor.
- Type
32-bit Integer
- Default
5
- Valid Range
Should be less than
osd mon report interval max
osd mon ack timeout
- Description
The number of seconds to wait for a Ceph Monitor to acknowledge a request for statistics.
- Type
32-bit Integer
- Default
30